Product featuresThe special pipe design and reduced installation design are adopted to reduce pressure pulsation and lower noise. The motor is of immersion type, eliminating the noise during motor shutdown. An external closed sound insulation design is employed to reduce the transmission of operating noise. The open measurement at 1 meter is less than 75 dB.
Each piston can adjust its output flow according to the external demand flow. When in minimum standby mode, it can save up to 60% of energy.
Developed specifically for various working conditions with significant fluctuations in external pressure and large changes in flow load, it features stable pressure, low pulsation, high efficiency, and can meet the various needs of users.
From a high-flow system of 30L/min to 600L/min, it can meet the usage requirements of various test benches; multiple large pumps can be connected in parallel to meet the flow demands of 6000L/min and above, enabling the construction of large-scale centralized pump houses.
Each pumping station is designed with multiple motor piston pump modules. Each module can operate independently, intelligently saving energy for users and making maintenance and upkeep more convenient.
It is controlled by PLC and operated via touch screen. The pumping station can operate independently.
It can collect and process real-time signals such as temperature, pressure, liquid level, and filtration. It can also issue alarms and shut down the equipment in case of abnormal situations such as overpressure, underpressure, low liquid level, and oil leakage during the usage process.
It can achieve parallel arrangement of multiple pumping stations, with a compact structure and a small footprint, approximately the installation space required.
The operation can be controlled on the computer through software.
Key technical indicators| Product model | Traffic | Rated pressure | Rated power | Pressure fluctuations | Cooling method | Cooling method |
| CPVF-0-30 | 30L/min | 10-21Mpa | 14.7KW | 0-1.5Mpa | Water cooling | No |
| CPVF-0-50 | 50L/min | 10-21Mpa | 25.4KW | 0-1.5Mpa | Water cooling | No |
| CPVF-0-100 | 100L/min | 10-21Mpa | 45KW | 0-1.5Mpa | Water cooling | No |
| CPVF-2-300 | 300L/min | 21Mpa | 135KW | 0-1.5Mpa | Water cooling | Mirror images of each other |
| CPVF-1-300 | 300L/min | 21Mpa | 135KW | 0-1.5Mpa | Water cooling | Mirror images of each other |
| CPVF-1-400 | 400L/min | 21Mpa | 180KW | 0-1.5Mpa | Water cooling | Mirror images of each other |
| CPVF-2-400 | 400L/min | 21Mpa | 180KW | 0-1.5Mpa | Water cooling | No |
| CPVF-1-500 | 500L/min | 21Mpa | 225KW | 0-1.5Mpa | Water cooling | No |
| CPVF-2-500 | 500L/min | 21Mpa | 225KW | 0-1.5Mpa | Water cooling | Mirror images of each other |
| CPVF-3-600 | 600L/min | 21Mpa | 270KW | 0-1.5Mpa | Water cooling | No |
Usage RequirementsOperating environment: Ambient temperature: 0℃ - 40℃, Relative humidity: < 95%, Atmospheric pressure: 85 - 120 kPa
Power requirements: Three-phase power: AC380V, 50Hz; Single-phase power: AC220V, 50Hz. Other requirements: This power supply should not be affected by power transients caused by other devices.
Cooling water requirements: Water quality requirements: Industrial softened water, inlet water temperature: 4 - 32℃, inlet water pressure: 0.3 - 0.6 Mpa, inlet water flow rate: approximately 6 m³/h per 45 kW, inlet and outlet water channels: Each pumping station has separate inlet and outlet water ports.